 New Product
Digital Fiber Sensors
E3X-DA-S
An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection.
* "GIGA RAY" Giga Power Lighting Element to create a wide variety of value. * Power turning to easily set the optimum light level. * Active Thereshold Control (ATC) reduces incorrect operation due to dust, oil, or other influences. * Automatic Power Control (APC) is always enabled to stabilize emitter power with high accuracy.
Ordering Information
Amplifier Units [Dimensionspage 23]
Type Appearance Connecting method Model NPN output PNP output Applicable wire-saving connector (sold separately) Type Model
Pre-wired (2 m) Standard models Wire-saving connector
E3X-DA21-S 2M
E3X-DA51-S 2M
---
---
Master connector E3X-DA7-S E3X-DA9-S Slave connector
E3X-CN21 E3X-CN22
Pre-wired (2 m) Ultra-long-term APC models Wire-saving connector
E3X-DA21R-S 2M
E3X-DA51R-S 2M
---
---
Master connector E3X-DA7R-S E3X-DA9R-S Slave connector
E3X-CN21 E3X-CN22
Pre-wired (2 m) High-speed response models Wire-saving connector
E3X-DA21F-S 2M
E3X-DA51F-S 2M
---
---
Master connector E3X-DA7F-S E3X-DA9F-S Slave connector
E3X-CN11 E3X-CN12
An Wire-saving connector sold separately is required.
1
E3X-DA-S
Wire-saving connector (sold separately)
Type Master connector Appearance
Protection stickers attached [Dimensionspage 25]
Cable length No. of conductors 4 Model E3X-CN21
Slave connector 2m Master connector
2
E3X-CN22
3
E3X-CN11
Slave connector
1
E3X-CN12
Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.
Accessories (sold separately)
Mounting Brackets [Dimensionspage 26]
Appearance Model E39-L143 Quantity 1
End Plate [Dimensionspage 26]
Appearance Model PFP-M Quantity 1
Product Overview
: Strong point of the model Types Connecting method Item Input/output Output Sensing distance with E32-T11R Sensing distance with E32-D11R Giga Power (GIGA RAY) High-speed response Power tuning Automatic power control (APC) Timer ATC Function Key lock Easy key lock (switchable) APC margin display Slow-motion display ----------(Ultra-long-term APC) Models External input Standard models Pre-wired E3X-DA21-S E3X-DA51-S 1 input 2 outputs 280 to 2,000 mm (Depends on response time) 100 to 840 mm (Depends on response time) (Margin: x 160) (80 s) (80 s) (46 s) Wire-saving connector E3X-DA7-S E3X-DA9-S --Ultra-long-term APC models Pre-wired E3X-DA21R-S E3X-DA51R-S 1 input Wire-saving connector E3X-DA7R-S E3X-DA9R-S --: Provided ---: Not provided High-speed response models Pre-wired E3X-DA21F-S E3X-DA51F-S --1 output 280 mm (Only Super-high-speed Mode) 100 mm (Only Super-high-speed Mode) Wire-saving connector E3X-DA7F-S E3X-DA9F-S
1 output and 1 APC alarm output 140 to 1,000 mm (Depends on response time) 50 to 420 mm (Depends on response time)
Performance
2
E3X-DA-S
Ratings and Specifications
Amplifier Units
Type Item Light source (wavelength) Power supply voltage Power consumption Control output / APC alarm output External input 1 Protection circuits Super-highspeed Mode 3 High-speed ReMode sponse Standard Mode time High-resolution Mode Tough Mode Sensitivity setting Power tuning Differential detection Automatic power control (APC) Timer ATC Functions APC margin display Slow-motion display Zero reset Resetting settings Mutual interference prevention ECO Mode 5 External input setting 1 Output setting Model Standard models E3X-DA@-S (@: 21/51/7/9) Red,4-element LED (625 nm) 12 to 24 VDC 10%, ripple (p-p) 10% max. Normal mode : 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC) Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC) Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 2 V max. No-voltage input (contact / transistor) 2 Operate or reset: 80 s Operate or reset: 250 s Operate or reset: 1 ms Operate or reset: 4 ms Operate or reset: 16 ms Teaching or manual method Light emission power and reception gain, digital control method Switchable between Single-edge and Double-edge Detection Modes. Single edge: Set to 250 s, 500 s, 1 ms, 10 ms, or 100 ms. Double edge: Set to 500 s, 1 ms, 2 ms, 20 ms, or 200 ms Always enabled. High-speed control of emission current Wide-range APC for the E3X-DA@R-S Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) Provided ----Negative values can be displayed. (Threshold value is shifted.) Select from initial reset (factory defaults) or user reset (saved settings). Possible for up to 10 units 4 --Provided --Provided ------NPN output: Operate: 46 s, Reset: 48 s PNP output: Operate: 51 s, Reset: 53 s Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection Ultra-long-term APC models E3X-DA@R-S (@: 21/51/7/9) High-speed response models E3X-DA@F-S (@: 21/51/7/9)
Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF). Select from teaching operations, power tuning, zero reset, emitter OFF, or ATC start. Select from output for each channel, area output, or self-diagnosis. --Operation indicator for channel 1(orange) APC alarm output indicator (orange) Operation indicator for channel 1(orange) Power tuning indicator (orange) ---
Operation indicator for channel 1(orange) Operation indicator for channel 2(orange) 1. Only for Pre-wired models. 2. The following details apply to inputs. Indicator
Contact input (relay or switch) NPN PNP ON: Shorted to 0 V (sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. ON: Shorted to Vcc (sinking current: 3 mA max.). OFF: Open or shorted to 0 V.
Non-contact input (transistor) ON: 1.5 V max. (sourcing current: 1 mA max.) OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.) ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.) OFF: 1.5 V max. (leakage current: 0.1 mA max.)
3. The communications function and mutual interference prevention function are disabled if detection is set to Super-high-speed mode. 4. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units. 5. For the E3X-DA@-S (@: 21/51/7/9), the rated sensing distance is approximately 1/2 and the incident level is approximately 1/3 of the normal levels when ECO mode is enabled.
3
E3X-DA-S
Item Digital display Display orientation Key lock
Model
E3X-DA@-S (@: 21/51/7/9)
E3X-DA@R-S (@: 21/51/7/9)
E3X-DA@F-S (@: 21/51/7/9)
Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 17.) Switching between normal / reversed display is possible. Key lock Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. 16 (The ambient temperature specification depends on the number of connected units.) Operating: Groups of 1 to 2 Amplifiers: -25 to 55C Groups of 3 to 10 Amplifiers: -25 to 50C Groups of 11 to 16 Amplifiers: -25 to 45C Storage: -30 to 70C (with no icing or condensation) Operating and storage: 35% to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC at 50/60 Hz for 1 minute Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Destruction: 500 m/s2 for 3 times each in X, Y and Z directions IEC 60529 IP50 (with Protective Cover attached) Pre-wired (standard length 2 m) or Wire-saving connector Pre-wired models: Approx. 100 g, Wire-saving connector models: Approx. 55 g Polybutylene terephthalate (PBT) Polycarbonate (PC) Instruction Manual Key lock / Easy key lock.
Ambient illumination (Receiver side) Maximum connectable Units Ambient temperature range Ambient humidity range Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (packed state) Materials Case Cover
Accessories
Wire-saving connectors
Item Rated current Rated voltage Contact resistance No. of insertions Materials Housing Contacts Model 2.5 A 50 V 20 m max. (20 mVDC max., 100 mA max.) (The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor resistance of the cable.) Destruction: 50 times (The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.) Polybutylene terephthalate (PBT) Phosphor bronze / gold-plated nickel Approx. 55 g Approx. 25 g E3X-CN21/22/11 E3X-CN12
Weight (packed state)
4
E3X-DA-S
Sensing Distance
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit Screw-shaped model Sensing method Throughbeam models Size M3 Sensing direction Straight Right angle M4 Straight Right angle M3 Straight M4 Reflective models M6 Straight Right angle Model E32-T21R 2M E32-T11N 2M E32-T11R 2M E32-TC200 2M E32-T11L 2M E32-C31N 2M E32-D21R 2M E32-C31 2M E32-D211R 2M E32-D11N 2M E32-C11N 2M E32-D11R 2M E32-DC200 2M E32-CC200 2M E32-D11L 2M Tough mode 450 2,000 2,000 2,800 4,000 110 140 330 140 840 780 840 1,400 1,400 1,820 Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 300 1,400 1,400 2,000 3,400 80 100 240 100 600 560 600 1,000 1,000 1,300 Standard mode 250 1,000 1,000 1,550 2,700 50 60 150 60 350 350 350 600 600 800 High-speed mode 150 700 700 1,000 1,740 46 40 100 40 240 320 240 400 400 520 Super-highspeed mode 60 280 280 400 700 14 16 44 16 100 100 100 180 180 220
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit Flat model Sensing method Sensing direction Top view Throughbeam models Side view Flat view Top view Reflective models Side view Flat view Size Standard Small Standard Small Standard Small Standard Small Standard Small Standard Small Model E32-T15XR 2M E32-T25XR 2M E32-T15YR 2M E32-T25YR 2M E32-T15ZR 2M E32-T25ZR 2M E32-D15XR 2M E32-D25XR 2M E32-D15YR 2M E32-D25YR 2M E32-D15ZR 2M E32-D25ZR 2M Amplifier Unit Sensing direction Top view Side view Tough mode 2,000 450 750 170 750 170 840 140 200 40 200 40 Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 1,400 300 550 120 550 120 600 100 140 28 140 28 Standard mode 1,000 250 450 100 450 100 350 60 100 16 100 16 High-speed mode 700 150 260 50 260 50 240 40 52 10 52 10 Super-highspeed mode 280 60 100 20 100 20 100 16 24 4 24 4
Fiber Unit Cylindrical model Sensing method Throughbeam models Size 1 3 1 3 1.5 Top view Reflective models Side view 2 3 2 6
E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 300 1,400 120 550 100 240 100 500 52 160 Standard mode 250 1,000 100 450 60 150 60 300 30 100 High-speed mode 150 700 50 260 40 100 40 200 20 60 Super-highspeed mode 60 280 20 100 16 44 16 90 8 28
Model E32-T223R 2M E32-T12R 2M E32-T24R 2M E32-T14LR 2M E32-D22B 2M E32-D32 2M E32-D22R 2M E32-D32L 2M E32-D24R 2M E32-D14LR 2M Amplifier Unit
Tough mode 450 2,000 170 750 140 330 140 700 70 220
Fiber Unit Model equipped with sleeve Sensing method Throughbeam models Sleeve size 0.25 x 5 0.5 x 40 0.9 x 40 1.2 x 90 0.5 x 15 Reflective models 0.8 x 15 1.2 x 40 2.5 x 90 Mounting size 3 M3 M4 2 3 M3 M6
E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 25 110 300 1,400 10 50 100 600 Standard mode 20 90 250 1,000 6 30 60 350 High-speed mode 12 50 150 700 4 20 40 240 Super-highspeed mode 8 20 60 280 2 8 16 100
Model E32-T333-S5 1M E32-T33 1M E32-TC200F4R 2M E32-TC200BR 2M E32-D331 2M E32-D33 2M E32-DC200F4R 2M E32-DC200BR 2M
Tough mode 35 150 450 2,000 14 70 140 840
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
5
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9)
Fiber Unit Movable section (Flexibility) Sensing Type method Screw-shaped model Throughbeam models Cylindrical model Flat model Screw-shaped model Reflective models Cylindrical model Flat model Fiber Unit Heat-resistance model Sensing Operating method temperature 100C
E3X-DA@F-S(@: 21/51/7/9)
Amplifier Unit Size M3 M4 1.5 3 Standard Small M3 M4 M6 1.5 3 Standard Small Model E32-T21 2M E32-T11 2M E32-T22B 2M E32-T12B 2M E32-T15XB 2M E32-T25XB 2M E32-D21 2M E32-D21B 2M E32-D11 2M E32-D22B 2M E32-D221B 2M E32-D15XB 2M E32-D25XB 2M Amplifier Unit Lens Model E32-T51R 2M E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51 2M E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 E32-T54 2M E32-T81R-S 2M E32-T61-S 2M E32-T61-S 2M + E39-F1 E32-T61-S 2M E32-T61-S 2M + E39-F16 E32-D51R 2M E32-D51 2M E32-D81R 2M E32-D61 2M E32-D73 2M Tough mode 1,600 4,000 4,000 2,800 4,000 4,000 840 1,000 1,680 4,000 1,680 4,000 670 1,120 420 420 280 Tough mode 680 2,500 680 2,500 2,500 500 140 300 840 140 300 840 240 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 480 400 220 90 1,800 1,350 900 360 480 400 220 90 1,800 1,350 900 360 1,800 1,350 900 360 360 300 170 70 100 60 40 16 220 140 90 40 600 350 240 100 100 60 40 16 220 140 90 40 600 350 240 100 170 100 60 30 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 1,100 800 560 225 4,000 4,000 3,900 1,500 4,000 4,000 4,000 4,000 2,000 1,500 1,000 400 4,000 4,000 2,300 1,400 4,000 4,000 4,000 4,000 600 450 300 120 720 550 360 140 1,200 900 600 240 4,000 4,000 4,000 1,800 1,200 900 600 240 4,000 4,000 4,000 3,100 480 280 190 80 800 450 320 144 300 180 120 54 300 180 120 54 200 120 80 36
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Throughbeam models
150C
--Lens High-power lens --Lens High-power lens ---
200C Lens --High-power lens
350C 100C 150C 200C 350C 400C
Reflective models
---
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit Chemical-resistance / Oil-resistance model Sensing Type method 5 7.2 5 Heat-resistance model Through5 beam Side view models M4 Chemical-resistance cable M4 Right angle Chemical-resistance cable 6 7 Reflective Side view models M6 Chemical-resistance cable Amplifier Unit Model E32-T12F 2M E32-T11F 2M E32-T51F 2M E32-T14F 2M E32-T11U 2M E32-T11NU 2M E32-D12F 2M E32-D14F 2M E32-D11U 2M E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highTough mode mode mode mode speed mode 4,000 1 4,000 1 4,000 1 1,600 4,000 1 4,000 1 4,000 1 4,000 1 2,600 1,000 4,000 1 1,400 2,500 1,440 --- 2 --- 2 840 3,600 1,000 1,800 1,040 320 140 600 2,800 800 1,350 800 190 80 350 1,800 500 900 520 130 60 240 700 200 360 200 60 20 100
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Fiber Unit Vacuum-resistance model Sensing Operating ambient method temperature Throughbeam models 120C 200C Amplifier Unit Sensing direction Top view Right angle Model E32-T51V 1M E32-T51V 1M + E39-F1V E32-T54V 1M E32-T84SV 1M Tough mode 720 3,780 580 1,760 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 520 400 260 100 2,700 2,000 1,360 520 420 250 200 70 1,250 950 640 260
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
6
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit Long distance / Dust resistance (High-power), Detection through gaps (Narrow vision field) Sensing method Type High-power (integrated unit) Sensing direction / Lens type Top view Side view High-power Ultrahigh-power High-power Ultrahigh-power Side view High-power Ultrahigh-power Side view High-power Ultrahigh-power Throughbeam models High-power (with lens unit) Side view High-power Ultrahigh-power Side view High-power Ultrahigh-power High-power Ultrahigh-power Side view High-power Ultrahigh-power Side view Narrow vision field (aperture angle: 4) Reflective models High-power Top view Side view Top view E32-T14 2M E32-T11N 2M + E39-F1 E32-T11N 2M + E39-F16 E32-T11R 2M + E39-F1 E32-T11R 2M + E39-F16 E32-T11R 2M + E39-F2 E32-TC200 2M + E39-F1 E32-TC200 2M + E39-F16 E32-TC200 2M + E39-F2 E32-T11 2M + E39-F1 E32-T11 2M + E39-F16 E32-T11 2M + E39-F2 E32-T11U 2M + E39-F1 E32-T11U 2M + E39-F16 E32-T11U 2M + E39-F2 E32-T11NU 2M + E39-F1 E32-T11NU 2M + E39-F16 E32-T81R-S 2M + E39-F1 E32-T81R-S 2M + E39-F16 E32-T81R-S 2M + E39-F2 E32-T61-S 2M + E39-F1 E32-T61-S 2M + E39-F16 E32-T61-S 2M + E39-F2 E32-T22S 2M E32-T24S 2M E32-D16 2M Model E32-T17L 10M Tough mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000 2 1,450 4,000 2 4,000 2 2,350 4,000 2 4,000 2 2,300 4,000 2 4,000 2 2,300 4,000 2 4,000 2 4,000 2 4,000 2 1,000 4,000 2 4,000 2 1,680 4,000 2 4,000 2 40 to 2,800 Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000 2 1,040 4,000 2 4,000 2 1,680 4,000 2 4,000 2 1,640 4,000 2 4,000 2 1,640 4,000 2 4,000 2 4,000 2 4,000 2 720 4,000 2 4,000 2 1,200 4,000 2 3,500 40 to 2,000 Standard mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000 2 800 4,000 2 4,000 2 1,400 4,000 2 4,000 2 1,320 4,000 2 4,000 2 1,320 4,000 2 4,000 2 4,000 2 4,000 2 550 4,000 2 4,000 2 900 3,800 2,600 40 to 1,400 High-speed mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000 2 500 4,000 2 4,000 2 900 4,000 2 4,000 2 860 4,000 2 4,000 2 860 2,600 4,000 2 2,700 4,000 2 360 4,000 2 4,000 2 600 2,500 1,740 40 to 900 Super-highspeed mode 8,000 1,800 2,000 3,600 2,000 3,600 200 3,000 4,000 2 320 1,860 4,000 2 320 1,860 4,000 2 320 1,000 2,800 1,000 1,800 140 1,800 3,100 240 1,000 700 40 to 480
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. 2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit Minute object detection (Small-spot model) Sensing method Spot diameter (mm) 0.1 to 0.6 (Variable) 0.3 to 1.6 (Variable) 0.1 Reflective models 0.2 0.5 6 4 Parallel light 3 Focal length (mm) 6 to 15 10 to 30 5 7 17 7 17 50 0 to 20 50 Model E32-C42 1M + E39-F3A E32-C42 1M + E39-F17 E32-C42S 1M E32-C41 1M + E39-F3A-5 E32-C41 1M + E39-F3B E32-C31 2M + E39-F3A-5 E32-C31 2M + E39-F3B E32-L15 2M E32-C31 2M + E39-F3C E32-C11N 2M + E39-F18 E32-CC200 2M + E39-F18 Amplifier Unit Sensing direction Side view Flat view Side view Tough mode Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm Spot diameter of 0.1 mm at 5 mm Spot diameter of 0.1 mm at 7 mm Spot diameter of 0.2 mm at 17 mm Spot diameter of 0.5 mm at 7 mm Spot diameter of 0.5 mm at 17 mm Spot diameter of 6 mm at 50 mm Sensing distance in all mode (40 to 100 mm) Spot diameter of 4 mm max. at 0 to 20 mm Spot diameter of 3 mm at 50 mm Spot diameter of 3 mm at 50 mm E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 2,200 2,000 3,400 500 Standard mode 1,700 1,500 2,600 300 High-speed mode 1,120 960 1,700 200 Super-highspeed mode 440 380 680 90
Fiber Unit Area-sensing (Area beam) Sensing method Throughbeam models Reflective models Area range 11 mm 30 mm 11 mm
Model E32-T16PR 2M E32-T16JR 2M E32-T16WR 2M E32-D36P1 2M
Tough mode 3,100 2,750 4,000 700
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
7
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9)
Fiber Unit Sensing method Reflective models Sensing direction Flat view Top view Flat view
E3X-DA@F-S(@: 21/51/7/9)
Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) Tough mode High-resolution mode Standard mode 0 to 4 5.4 to 9 (center 7.2) 2 to 6 (center 4) High-speed mode Super-highspeed mode 0 to 12
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Detection without background interference (Convergent-reflective) Size Standard Small --Model E32-L16-N 2M E32-L24S 2M E32-L25L 2M E32-L24L 2M
0 to 15
If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit Detection of transparent objects (Retro-reflective) Sensing method Retroreflective models Type Square Small Film detection 2 Model E32-R16 5M + E39-R1 (attached) 1 E32-R21 2M + E39-R3 (attached) 1 E32-C31 2M + E39-F3R+E39-RP37 1 E32-C31 2M + E39-F3R+E39-RSP1 1 250 450 Tough mode Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode 150 to 1,500 10 to 250 200 300 --100 High-speed mode Super-highspeed mode
1. When using a highly reflective object, light reflected from the object may affect the sensor. 2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens Unit. Be sure to check operation in advance.
Fiber Unit FPD / Semiconductor / Solar battery industry Sensing method Application Glass detection 70C Glass substrate alignment 300C Reflective models 70C Glass substrate mapping 150C 300C 60C WET process 70C 85C Throughbeam models Operating temperature Model E32-L16-N 2M E32-L16-N 2M E32-A08 2M E32-A08H2 3M E32-A09 2M E32-A09H 2M E32-A09H2 2M E32-L11FP 5M E32-L12FS 5M E32-L11FS 5M E32-A03 2M Wafer mapping 70C E32-A03-1 2M E32-A04 2M E32-A04-1 2M Tough mode Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode 0 to 12 0 to 12 -----------
0 to 15 0 to 15 10 to 20 10 to 20 15 to 38 15 to 38 20 to 30 8 to 20 mm from end of lens (recommended: 11 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 3,220 3,220 1,280 1,280 2,300 2,300 920 920 1,780 1,780 680 680 1,200 1,200 450 450
500 500 200 200
If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit Liquid-level detection model Sensing method Sensing direction Pipe diameter No limit Reflective Mounted to pipe models Wet 8 to 10 mm --Model E32-D36T 5M 1, 2 E32-L25T 2M E32-D82F1 4M 1 Tough mode Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode
Applicable pipe: Transparent (no restriction on diameter) Applicable pipe: Transparent pipe with diameter of 8 to 10 mm, recommended pipe wall thickness: 1 mm Wet model
1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received. 2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
8
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit Screw-shaped model Sensing method Throughbeam models Size M3 Sensing direction Straight Right angle M4 Straight Right angle M3 Straight M4 Reflective models M6 Straight Right angle Model E32-T21R 2M E32-T11N 2M E32-T11R 2M E32-TC200 2M E32-T11L 2M E32-C31N 2M E32-D21R 2M E32-C31 2M E32-D211R 2M E32-D11N 2M E32-C11N 2M E32-D11R 2M E32-DC200 2M E32-CC200 2M E32-D11L 2M Fiber Unit Flat model Sensing method Sensing direction Top view Throughbeam models Side view Flat view Top view Reflective models Side view Flat view Size Standard Small Standard Small Standard Small Standard Small Standard Small Standard Small Model E32-T15XR 2M E32-T25XR 2M E32-T15YR 2M E32-T25YR 2M E32-T15ZR 2M E32-T25ZR 2M E32-D15XR 2M E32-D25XR 2M E32-D15YR 2M E32-D25YR 2M E32-D15ZR 2M E32-D25ZR 2M Amplifier Unit Sensing direction Top view Side view Tough mode 1,000 220 370 85 370 85 420 70 100 20 100 20 Amplifier Unit Tough mode 220 1,000 1,000 1,400 2,000 55 70 165 70 420 390 420 700 700 910 Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 160 700 700 1,000 1,700 40 50 120 50 300 280 300 500 500 650 Standard mode 130 500 530 760 1,350 25 30 75 30 175 175 170 300 300 400 High-speed mode 75 350 350 500 870 23 20 50 20 120 160 120 200 200 260 Super-highspeed mode 30 140 140 200 350 7 8 22 8 50 50 50 90 90 110
E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 700 160 270 60 270 60 300 50 70 14 70 14 Standard mode 530 130 210 50 210 50 170 30 40 8 40 8 High-speed mode 350 75 130 25 130 25 120 20 26 5 26 5 Super-highspeed mode 140 30 50 10 50 10 50 8 12 2 12 2
Fiber Unit Cylindrical model Sensing method Throughbeam models Size 1 3 1 3 1.5 Top view Reflective models Side view 2 3 2 6
E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 160 700 60 270 50 120 50 250 26 80 Standard mode 130 530 50 210 30 75 30 150 15 45 High-speed mode 75 350 25 130 20 50 20 100 10 30 Super-highspeed mode 30 140 10 50 8 22 8 45 4 14
Model E32-T223R 2M E32-T12R 2M E32-T24R 2M E32-T14LR 2M E32-D22B 2M E32-D32 2M E32-D22R 2M E32-D32L 2M E32-D24R 2M E32-D14LR 2M Amplifier Unit
Tough mode 220 1,000 85 370 70 160 70 350 35 110
Fiber Unit Model equipped with sleeve Sensing method Throughbeam models Sleeve size 0.25 x 5 0.5 x 40 0.9 x 40 1.2 x 90 0.5 x 15 Reflective models 0.8 x 15 1.2 x 40 2.5 x 90 Mounting size 3 M3 M4 2 3 M3 M6
E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 12 55 160 700 5 25 50 300 Standard mode 10 45 130 530 3 16 30 170 High-speed mode 6 25 75 350 2 10 20 120 Super-highspeed mode 4 10 30 140 0.8 4 8 50
Model E32-T333-S5 1M E32-T33 1M E32-TC200F4R 2M E32-TC200BR 2M E32-D331 2M E32-D33 2M E32-DC200F4R 2M E32-DC200BR 2M
Tough mode 17 75 220 1,000 7 35 70 420
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
9
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit Movable section (Flexibility) Sensing Type method Screw-shaped model Throughbeam models Cylindrical model Flat model Screw-shaped model Reflective models Cylindrical model Flat model Fiber Unit Heat-resistance model Sensing Operating method temperature 100C Amplifier Unit Size M3 M4 1.5 3 Standard Small M3 M4 M6 1.5 3 Standard Small Model E32-T21 2M E32-T11 2M E32-T22B 2M E32-T12B 2M E32-T15XB 2M E32-T25XB 2M E32-D21 2M E32-D21B 2M E32-D11 2M E32-D22B 2M E32-D221B 2M E32-D15XB 2M E32-D25XB 2M Amplifier Unit Lens --Lens High-power lens --Lens High-power lens --200C Lens --High-power lens Model E32-T51R 2M E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51 2M E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 E32-T54 2M E32-T81R-S 2M E32-T61-S 2M E32-T61-S 2M + E39-F1 E32-T61-S 2M E32-T61-S 2M + E39-F16 E32-D51R 2M E32-D51 2M E32-D81R 2M E32-D61 2M E32-D73 2M Tough mode 800 4,000 4,000 1,400 4,000 4,000 420 500 840 4,000 840 4,000 330 560 210 210 140 Tough mode 340 1,250 340 1,250 1,250 250 70 150 420 70 150 420 120 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 240 200 110 45 900 680 450 180 240 200 110 45 900 680 450 180 900 680 450 180 180 150 85 35 50 30 20 8 110 70 45 20 300 170 120 50 50 30 20 8 110 70 45 20 300 170 120 50 85 50 30 15 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 560 425 280 110 3,900 2,900 1,900 760 4,000 4,000 3,600 1,400 1,000 760 500 200 3,400 2,660 1,150 700 4,000 4,000 4,000 2,600 300 230 150 60 360 280 180 70 600 450 300 120 4,000 3,400 2,200 900 600 450 300 120 4,000 4,000 3,900 1,500 240 135 95 40 400 230 160 72 150 90 60 27 150 90 60 27 100 60 40 18
Throughbeam models
150C
350C 100C 150C 200C 350C 400C
Reflective models
---
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit Chemical-resistance / Oil-resistance model Sensing Type method 5 7.2 5 Heat-resistance model Through5 beam Side view models M4 Chemical-resistance cable M4 Right angle Chemical-resistance cable 6 7 Reflective Side view models M6 Chemical-resistance cable Amplifier Unit Model E32-T12F 2M E32-T11F 2M E32-T51F 2M E32-T14F 2M E32-T11U 2M E32-T11NU 2M E32-D12F 2M E32-D14F 2M E32-D11U 2M E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highTough mode mode mode mode speed mode 4,000 1 3,000 2,000 800 4,000 1 3,500 2,500 2,000 1,300 520 2,500 700 1,250 720 --- 2 --2
1,800 500 900 520 160 70 300
1,400 400 680 400 95 40 170
900 250 450 260 65 30 120
350 100 180 100 30 10 50
420
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used.
Fiber Unit Vacuum-resistance model Sensing Operating ambient method temperature Throughbeam models 120C 200C Amplifier Unit Sensing direction Top view Right angle Model E32-T51V 1M E32-T51V 1M + E39-F1V E32-T54V 1M E32-T84SV 1M Tough mode 360 1,890 290 880 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 260 200 130 50 1,350 1,000 680 260 210 130 100 35 630 480 320 130
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
10
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit Long distance / Dust resistance (High-power), Detection through gaps (Narrow vision field) Sensing method Type High-power (integrated unit) Sensing direction / Lens type Top view Side view High-power Ultrahigh-power High-power Ultrahigh-power Side view High-power Ultrahigh-power Side view High-power Ultrahigh-power Throughbeam models High-power (with lens unit) Side view High-power Ultrahigh-power Side view High-power Ultrahigh-power High-power Ultrahigh-power Side view High-power Ultrahigh-power Side view Narrow vision field (aperture angle: 4) Reflective models High-power Top view Side view Top view E32-T14 2M E32-T11N 2M + E39-F1 E32-T11N 2M + E39-F16 E32-T11R 2M + E39-F1 E32-T11R 2M + E39-F16 E32-T11R 2M + E39-F2 E32-TC200 2M + E39-F1 E32-TC200 2M + E39-F16 E32-TC200 2M + E39-F2 E32-T11 2M + E39-F1 E32-T11 2M + E39-F16 E32-T11 2M + E39-F2 E32-T11U 2M + E39-F1 E32-T11U 2M + E39-F16 E32-T11U 2M + E39-F2 E32-T11NU 2M + E39-F1 E32-T11NU 2M + E39-F16 E32-T81R-S 2M + E39-F1 E32-T81R-S 2M + E39-F16 E32-T81R-S 2M + E39-F2 E32-T61-S 2M + E39-F1 E32-T61-S 2M + E39-F16 E32-T61-S 2M + E39-F2 E32-T22S 2M E32-T24S 2M E32-D16 2M Model E32-T17L 10M Tough mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000
2
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 20,000 1 4,000 2 4,000 2 4,000 2 4,000 2 4,000 2 520 4,000 2 4,000 2 840 4,000 2 4,000 2 820 4,000 2 4,000 2 820 2,600 4,000 2 2,650 4,000 2 360 4,000 2 4,000 2 600 2,500 1,750 40 to 1,000 Standard mode 20,000 1 3,400 3,700 4,000 2 3,700 4,000 2 400 4,000 2 4,000 2 700 3,600 4,000 2 660 3,600 4,000 2 660 2,000 4,000 2 2,100 3,600 280 3,400 4,000 2 450 1,900 1,300 40 to 700 High-speed mode 10,000 2,250 2,400 4,000 2 2,400 4,000 2 250 2,600 4,000 2 450 2,300 4,000 2 430 2,300 4,000 2 430 1,300 3,300 1,300 2,300 180 2,200 3,900 300 1,250 870 40 to 450 Super-highspeed mode 4,000 900 970 1,800 970 1,800 100 1,500 4,000 2 160 930 2,300 160 930 2,300 160 500 1,300 520 900 70 900 1,500 120 500 350 40 to 240
725 4,000 2 4,000 2 1,170 4,000 2 4,000 2 1,150 4,000 2 4,000 2 1,150 4,000 2 4,000 2 4,000 2 4,000 2 500 4,000 2 4,000 2 840 3,500 2,400 40 to 1,400
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. 2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit Minute object detection (Small-spot model) Sensing method Spot diameter (mm) 0.1 to 0.6 (Variable) 0.3 to 1.6 (Variable) 0.1 Reflective models 0.2 0.5 6 4 Parallel light 3 Focal length (mm) 6 to 15 10 to 30 5 7 17 7 17 50 0 to 20 50 Model E32-C42 1M + E39-F3A E32-C42 1M + E39-F17 E32-C42S 1M E32-C41 1M + E39-F3A-5 E32-C41 1M + E39-F3B E32-C31 2M + E39-F3A-5 E32-C31 2M + E39-F3B E32-L15 2M E32-C31 2M + E39-F3C E32-C11N 2M + E39-F18 E32-CC200 2M + E39-F18 Amplifier Unit Sensing direction Side view Flat view Side view Tough mode Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm Spot diameter of 0.1 mm at 5 mm Spot diameter of 0.1 mm at 7 mm Spot diameter of 0.2 mm at 17 mm Spot diameter of 0.5 mm at 7 mm Spot diameter of 0.5 mm at 17 mm Spot diameter of 6 mm at 50 mm Sensing distance in all mode (40 to 100 mm) Spot diameter of 4 mm max. at 0 to 20 mm Spot diameter of 3 mm at 50 mm Spot diameter of 3 mm at 50 mm E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode 1,100 980 1,700 250 Standard mode 840 750 1,300 150 High-speed mode 560 480 850 100 Super-highspeed mode 220 190 340 45
Fiber Unit Area-sensing (Area beam) Sensing method Throughbeam models Reflective models Area range 11mm 30mm 11mm
Model E32-T16PR 2M E32-T16JR 2M E32-T16WR 2M E32-D36P1 2M
Tough mode 1,550 1,370 2,000 350
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
11
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit Sensing method Reflective models Sensing direction Flat view Top view Flat view Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) Tough mode High-resolution mode Standard mode 0 to 4 5.4 to 9 (center 7.2) 2 to 6 (center 4) High-speed mode Super-highspeed mode 0 to 12 Detection without background interference (Convergent-reflective) Size Standard Small --Model E32-L16-N 2M E32-L24S 2M E32-L25L 2M E32-L24L 2M
0 to 15
If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit Detection of transparent objects (Retro-reflective) Sensing method Retroreflective models Type Square Small Film detection 2 Model E32-R16 5M + E39-R1 (attached) 1 E32-R21 2M + E39-R3 (attached) 1 E32-C31 2M + E39-F3R+E39-RP37 1 E32-C31 2M + E39-F3R+E39-RSP1 1 250 600 200 300 Tough mode Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode 150 to 1,500 10 to 250 150 225 100 150 50 75 High-speed mode Super-highspeed mode
1. When using a highly reflective object, light reflected from the object may affect the sensor. 2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens Unit. Be sure to check operation in advance.
Fiber Unit FPD / Semiconductor / Solar battery industry Sensing method Application Glass detection 70C Glass substrate alignment 300C Reflective models 70C Glass substrate mapping 150C 300C 60C WET process 70C 85C Throughbeam models Operating temperature Model E32-L16-N 2M E32-L16-N 2M E32-A08 2M E32-A08H2 3M E32-A09 2M E32-A09H 2M E32-A09H2 2M E32-L11FP 5M E32-L12FS 5M E32-L11FS 5M E32-A03 2M Wafer mapping 70C E32-A03-1 2M E32-A04 2M E32-A04-1 2M Tough mode Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode 0 to 12 0 to 12 10 to 20 10 to 20 15 to 38 15 to 38 20 to 30 8 to 20 mm from end of lens (recommended: 11 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 8 to 20 mm from end of lens (recommended: 11 mm) 1,610 1,610 640 640 1,150 1,150 460 460 890 890 340 340 600 600 225 225 250 250 100 100
0 to 15 0 to 15
If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit Liquid-level detection model Sensing method Sensing direction Pipe diameter No limit Reflective Mounted to pipe models Wet 8 to 10mm --Model E32-D36T 5M E32-L25T 2M E32-D82F1 4M Tough mode Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution mode Standard mode High-speed mode Super-highspeed mode
Applicable pipe: Transparent (no restriction on diameter) Applicable pipe: Transparent pipe with diameter of 8 to 10 mm, recommended pipe wall thickness: 1 mm Wet model
If a high level of light is received, perform power tuning to reduce the amount of light that is received. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
12
E3X-DA-S
I/O Circuit Diagrams
NPN Output
Model Operation mode Timing charts
ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads)
Operation selector
E3X-DA21-S
Display
Output circuit
Light-ON E3X-DA21-S E3X-DA21R-S E3X-DA21F-S Dark-ON
LIGHT ON (L-ON)
Operation indicator (orange) ch2
Brown Load Black Control output Load Orange ch1 Control output ch2 1 Pink Blue External input 2
Operation indicator (orange) ch1
Photoelectric Sensor main circuit
12 to 24 VDC
DARK ON (D-ON)
1. For the E3X-DA21R-S, this is the APC alarm output. This output does not exist on the E3X-DA21F-S. 2. This input does not exist the E3X-DA21F-S.
E3X-DA7-S
Light-ON E3X-DA7-S E3X-DA7R-S E3X-DA7F-S Dark-ON
LIGHT ON (L-ON)
Display Operation indicator (orange) ch1
Operation indicator (orange) ch2
Brown Load Black Control output Load Orange ch1 Control output ch2 Blue
Photoelectric Sensor main circuit
12 to 24 VDC
DARK ON (D-ON)
For the E3X-DA7R-S, this is the APC alarm output. This output does not exist on the E3X-DA7F-S.
PNP Output
Model Operation mode Timing charts
ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads)
Operation selector
E3X-DA51-S
Display
Output circuit
Operation indicator (orange) ch2 Brown External input 2 Pink Control output ch1 Black Orange ch2 1 Load Blue Load
Control output
Light-ON E3X-DA51-S E3X-DA51R-S E3X-DA51F-S Dark-ON
LIGHT ON (L-ON)
Operation indicator (orange) ch1
Photoelectric Sensor main circuit
12 to 24 VDC
DARK ON (D-ON)
1. For the E3X-DA51R-S, this is the APC alarm output. This output does not exist on the E3X-DA51F-S. 2. This input does not exist the E3X-DA51F-S.
E3X-DA9-S
Display Operation indicator (orange) ch2 Brown
Light-ON E3X-DA9-S E3X-DA9R-S E3X-DA9F-S Dark-ON
LIGHT ON (L-ON)
Operation indicator (orange) ch1
Photoelectric Sensor main circuit
Control output ch1 Black
Control output Orange ch2 Load
12 to 24 VDC
Blue
Load
DARK ON (D-ON)
For the E3X-DA9R-S, this is the APC alarm output. This output does not exist on the E3X-DA9F-S.
Note: 1. Operation with area settings is as follows: LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. 2. Timing Charts for Timer Settings (T: Set Time)
ON delay
Incident light No incident light L-ON ON OFF D-ON ON OFF T D-ON T
OFF delay
Incident light No incident light L-ON ON OFF ON OFF T D-ON T
One-shot
Incident light No incident light L-ON ON OFF ON OFF T T
ON delay and OFF delay
Incident light No incident light L-ON ON OFF D-ON ON OFF T2 T1 T1 T2
T1: ON-delay set time T2: OFF-delay set time T1 and T2 can be set separately.
13
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings, etc.
Operation Keys
Function setting operations UP DOWN MODE
Lock lever
Locks the fiber.
Operation Indicator (ch1) (orange)
Operation Indicator (ch2) (orange)
Channel Selector
Use to select the channel to display and set.
ON when output is ON. ON when output is ON. OFF when output is OFF. OFF when output is OFF.
Mode Selector
Use to select SET or RUN Mode.
Note: Nomenclature and operating procedures for the E3XDA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on pages 19 and 20.
Operating Procedure
1 Setting the Operation Mode
The operation mode is set in SET Mode. Refer to 5. Setting Functions on page 16.
To restore the default power setting:
Press the DOWN Key right after pressing the MODE Key.
PTUN
DOWN
MODE
Press both for 3 s.
OFF
Set the Channel Selector Switch to the desired channel before making any adjustments or settings.
"OFF" will flash twice.
2
Adjusting the Power (RUN Mode)
Incident level Threshold
The current incident light level can be adjusted near the power tuning target value (default: 2,000).
Confirm that the MODE Key setting is PTUN (power tuning). The default setting is PTUN. Refer to 5. Setting Functions on page 16. If power tuning is executed while SHS is selected for the detection function, the minimum power will be set.
This restores the default setting.
Setting Errors An error has occurred if one of the following displays appears after the progress bar is displayed.
Display
Flashes twice
Error
Over Error The incident light level is too low for the power tuning target value. Bottom Error The incident light level is too high for the power tuning target value.
Action
The power will not be tuned. The power can be increased up to approximately 5 times the incident light value. The power will be turned to the minimum level. The power can be decreased down to approximately 1/20th the incident light value.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
Incident level
Threshold (default) PTUN OVER
Flashes twice
MODE
3s
PTUN
BOTM
PTUN
Progress bar
Release the key after the progress bar is displayed.
Display changes after specific time.
3
Setting Thresholds Manually (RUN Mode)
A threshold can be set manually. A threshold can also be adjusted manually after teaching to fine-tune it.
Power tuning target value Incident level Threshold
Set the Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
Light level
Threshold (default)
This completes the adjustment.
UP
DOWN
Increases threshold.
Decreases threshold.
Even if the display method is changed, the threshold will appear on the sub-display when the key is pressed.
14
E3X-DA-S
4
Teaching the Threshold (SET Mode)
4-3. Teaching a Reflective Fiber Unit without a Workpiece
You can set the threshold to above the incident light level without a workpiece by the percentage set for the teaching level.
Refer to 5. Setting Functions on page 16.
There are five methods that can be used for teaching, as described below. Use the method most suitable for the application. Two-point teaching, positioning teaching, and automatic teaching can be performed in RUN Mode. For operating procedures, refer to the Instruction Manual provided with the product. An error has occurred if OVER or LO is displayed on the sub-display. If that occurs, repeat the operation from the beginning.
Set the SET/RUN Mode Selector Switch to SET.
SET
Incident level
Threshold
4-1. Setting the Threshold at Maximum Sensitivity
The threshold can be set to the maximum sensitivity. This is useful when the longest detection distance is required.
Set the SET/RUN Mode Selector Switch to SET.
SET
Incident level Threshold
UP
DOWN
With no workpiece:
TECH ----
Press either for 1 s.
"----" will be displayed.
UP DOWN
With no workpiece:
Press either for 3 s.
UP
DOWN
Press either for 3 s.
FULL
Threshold RFCT Threshold
The threshold that was set will flash twice.
The threshold that was set will flash twice.
Incident level Threshold
Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure.
Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure.
Incident level
Threshold
4-2. Teaching a Through-beam Fiber Unit without a Workpiece
You can set the threshold to below the incident light level without a workpiece by the percentage set for the teaching level.
Refer to 5. Setting Functions on page 16.
4-4. Two-point Teaching 4-5. Positioning Teaching
Two points in the following figures are detected, and the intermediate point of the light levels for the two points is set as the threshold.
Set the SET/RUN Mode Selector Switch to SET.
SET
Incident level Threshold
Set the SET/RUN Mode Selector Switch to SET.
SET
Incident level
Threshold
UP
DOWN
With no workpiece:
TECH ----
Press either for 1 s.
"----" will be displayed.
With a workpiece: For positioning teaching, place the workpiece where you want to position it.
UP
DOWN
Press either for 1 s.
Workpiece TECH ----
"----" will be displayed.
RUN
To RUN
THRU
Threshold
The threshold that was set will flash twice.
With no workpiece: For positioning teaching, place the workpiece where you want to position it.
2PNT
UP
DOWN
Press either for 1 s.
Threshold
Incident level
Threshold
This completes the setting procedure.
The threshold that was set will flash twice. Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure.
Incident level
Threshold
15
E3X-DA-S
5
Setting Functions (SET Mode)
Refer to 4. Teaching the Threshold on page 15.
Moving between Functions
Set the SET/RUN Mode Selector Switch to SET.
SET
The function transition boxes show the default settings. More functions may be displayed depending on the detailed settings.
Teaching
0. Operation mode
(To set the operation mode)
1. Detection
(To change response speed and detection precision)
2. Timer
(To use the timer setting)
3. Teaching level
(To change the teaching level)
11. External input memory
(Refer to the Instruction Manual provided with the sensor.)
MODE
4. ATC setting
(To change the ATC setting)
10. External input
(To change functions controlled using the external input)
9. Output setting
(To change outputs for channel 2)
8. ECO Mode
(To set the ECO Mode)
7. Display orientation
(To reverse the orientation of the display.)
6. Display switch
(To change the display method)
5. MODE Key
(To change the function of the MODE Key during operation)
When the settings have been completed
Set the SET/RUN Mode Selector Switch to RUN.
RUN
Functions
UP DOWN
Use the UP and DOWN Keys to change the settings.
Function
0. Operation mode 1. Detection
Differential edge (differential operation selected)
Setting (display)
Light ON: , Dark ON: , High-speed: , Standard: , , Tough: , Differential operation: , Double edge:
Description
Refer to 1. Setting the Operation Mode on page 14.
Super-high-speed: High-resolution: Single edge:
Used to change the response speed or detection precision. Used to set the edge to be detected. Used to set the differential response time.
Differential time
Single edge***250 s: , 500 s: , 1 ms: , 10 ms: , 100 ms: , Double edge***500 s: , 1 ms: , 2 ms: , 20 ms: , 200 ms: Timer disabled: , OFF-delay timer: ON-delay timer: , One-shot timer: ON-delay + OFF-delay timer: ,
2. Timer Time (timer enabled) 3. Teaching level 4. ATC setting Setting at Power-ON (ATC ON) 5. MODE Key
Power tuning target value (performing power tuning)
Used to enable or disable timers.
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments, Used to change timer settings when timers are enabled. 200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments The timer can be set from 1 to 5,000 ms. Setting range: ATC enabled: to , ATC disabled: , Used to change the threshold setting when teaching a Through-beam Fiber Unit without a workpiece or teaching a Reflective Fiber Unit without a workpiece. Used to enable or disable the ATC function. Used to set the processing to be performed when the power is turned ON. , Used to change the function of the MODE Key during RUN operation. Used to set target values during power tuning.
Refer to 2. Adjusting the Power on page 14.
No setting: , ATC start processing: Power tuning and ATC start processing: Executes power tuning: Executes a zero reset: Automatic teaching:
, , Two-point teaching: , ATC start:
Setting range: 100 to 3,900 (increments of 100) Maximum power :
The detection settings and MODE Key settings are the same for channel 1 and channel 2. Other functions can be set separately for each channel.
16
E3X-DA-S
Function
Incident level Threshold
Setting (display)
Description
Used to display the incident light level and the threshold. Used to display the incident light level as a percentage of the threshold and the threshold.
% incident level Threshold
PEAK
BOTM
Fixed interval
Used to display the peak and bottom levels of incident light within a set time. (Updated every 2 s.) Use to display the incident light peak level and no incident light bottom level. (Refreshed when output turns ON or OFF.) Analog bar display. The current detection status is displayed as an analog bar. The bar will lengthen from the right as ON status is reached. (ON: Red, OFF: Green) Used to display the current incident light level and the peak incident light level. Display changes at a fixed interval. Used to display the incident light level and the channel (unit number). Used to reverse the orientation of the display. , Used to enable or disable the ECO mode. Used to change the output details for channel 2. This setting will be disabled if the detection function is set to DIFF (i.e., differential operation) and the output will be used for an alarm output. Used to change the functions to be controlled using the external input. (Refer to the Instruction Manual provided with the sensor.)
6. Display switch
L-PE
D-BT
Detection status
Current incident level
PEAK
Fixed interval
Current incident Peak incident level level
Incident level Channel (unit number)
7. Display orientation 8. ECO Mode
Normal display: Lit degital display: OFF:
, Up/down reversed display: , Dimmed degital display:
9. Output setting
Each channel: , Output when the incident light level is between two thresholds: Self-diagnosis output: Through-beam, no-workpiece teaching: , Reflective, no-workpiece teaching: , Two-point teaching: , Automatic teaching: Power tuning: , Zero reset: , Light OFF: , ATC start: Write results to EEPROM: , Do not write results to EEPROM:
,
10. External input
,
11. External input memory
Used to set writing the results. (Refer to Instruction Manual provided with the product.)
17
E3X-DA-S
6
Convenient Functions
6-1. Setting the Digital Display to Zero (Zero Reset) 6-3. Resetting Settings (Initial Reset or User Reset)
All settings can be returned to the factory defaults or to user-saved settings.
Set the SET/RUN Mode Selector Switch to SET.
SET
UP DOWN
The incident light level on the main display can be set to 0. The incident light level and the threshold will both be shifted. This is useful when you want to set the reference display to zero.
Change the function to 0RST (zero reset) with the MODE Key. The default setting is PTUN. Refer to 5. Setting Functions on page 16.
Press both for 5 s.
RST
INIT
RST
USER
Set the SET/RUN Mode Selector Switch to RUN.
RUN
Factory setting
MODE
UP
DOWN MODE
3s
MODE
To return to original value for incident light level:
Set the SET/RUN Mode Selector Switch to RUN.
RUN
Factory setting
DOWN MODE
USER
YES?
USER
NO?
1
Press both for 3 s.
MODE UP DOWN MODE
6-2. Locking the Keys (Key Lock)
All key operations can be disabled.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
Factory setting
UP MODE
Perform user reset.
Operation canceled.
(The steps within the dotted lines can be used if settings have been saved by the user.)
Press both for 3 s.
2
INIT NO? INIT YES?
LOC
ON
MODE
UP
DOWN
MODE
"LOC ON" will flash twice and key operations will be disabled. To release the lock:
Set the SET/RUN Mode Selector Switch to RUN.
RUN
Factory setting
UP MODE
Operation canceled.
2
Press both for 3 s.
Settings initialized.
Saving User Settings
The current settings can be saved.
Set the SET/RUN Mode Selector Switch to SET.
SET
UP MODE
Press both for 5 s.
LOC
OFF SAVE YES? SAVE NO?
"LOC OFF" will flash twice and key operations will be enabled.
If a key is pressed while key operations are locked, "LOC ON" will flash twice on the display to indicate that key operations have been disabled. 1. Press the DOWN Key right after pressing the MODE Key. 2. Press the UP Key right after pressing the MODE Key.
MODE
UP
DOWN
MODE
The current settings are saved.
Operation canceled.
18
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@R-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings, etc.
Lock lever
Locks the fiber.
Operation Keys
Function setting operations
UP DOWN MODE
Operation Indicator (orange)
ON when output is ON. OFF when output is OFF.
APC alarm output indicator (orange)
ON when output is ON. OFF when output is OFF.
Easy key lock Selector
Select to lock or unlock settings.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18. For details, refer to the Instruction Manual provided with the product. This section shows functions specific to the E3X-DA@R-S.
Margin
APC
1
Locking the Keys (Easy Key Lock)
Before shipment, all key operation except for the MODE Keys can be disabled.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
Initial status
Margin
APC
Set the Easy Key Lock Selector Switch to Locked .
Locked
APC margin displayed in decrements of 10%
Note: Do not switch the lock while in SET Mode. Doing so will disable changing settings. If the lock is switched to in SET Mode, return to the unlock state, and then make the setting again.
Margin
APC
Unlocking
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
Set the Easy Key Lock Selector Switch to Unlocked .
Unlocked
APC margin of less than 10%
ALAT
The display switches every second.
APC
Margin
APC
2
Displaying the APC Margin
APC margin is 0%.
END
Displaying the APC margin can be useful for planning maintenance. When the APC margin is 0%, APC alarm output will turn ON, and the APC alarm output indicator will light regardless of the operation of the APC margin display.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
The display switches every 0.5 s.
APC
Set the Easy Key Lock Selector Switch to Locked .
Locked
Press the MODE Key or press nothing for 10 s.
MODE
Press the MODE Key to display the following for 10 s.
MODE
The display will return to the normal display.
Incident level
Threshold
19
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@F-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings, etc.
Lock lever
Locks the fiber
Operation Keys
Function setting operations
UP DOWN MODE
Operation Indicator (orange)
Power tuning indicator (orange)
Easy key lock Selector
Select to lock or unlock settings.
ON when setting is ON. ON when output is ON. OFF when output is OFF. OFF when setting is OFF.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18. For details, refer to the Instruction Manual provided with the product. This section shows functions specific to the E3X-DA@F-S.
1
Locking the Keys (Easy Key Lock)
Before shipment, all key operation except for the MODE Keys can be disabled.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
"A" is displayed when the output is ON or until approximately 10 s has elapsed. (Key operations will not be accepted in the status.)
STAT
A
Set the Easy Key Lock Selector Switch to Locked .
Locked
"STAT" will be displayed and the slow-motion display will start. The incident level in intervals of 17 s will be displayed for approximately 20 s every 160 ms (between 0.5 ms before ON to 1.5 ms after ON).
Incident level Threshold
Note: Do not switch the lock while in SET Mode. Doing so will disable changing settings. If the lock is switched to in SET Mode, return to the unlock state, and then make the setting again.
Unlocking
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN)
Incident level
Threshold
Set the Easy Key Lock Selector Switch to Unlocked .
Unlocked
Incident level
Threshold
2
Displaying the Change of the incident level
Changes of the incident level for high-speed workpiece detection can be displayed. This enables checking the margin level of light received and the workpiece ON time in slow motion.
Set the SET/RUN Mode Selector Switch to RUN.
RUN
(Factory-set to RUN) END Incident level Threshold
Press the MODE Key, or wait for the slow-motion display to end.
MODE
Set the Easy Key Lock Selector Switch to Locked .
Locked
The output ON time will be displayed.
Output ON time
Unit: s
END will be displayed.
Turn OFF the output or convey the workpieces.
Incident level
MODE
Threshold
Press the MODE key.
The display will return to the normal display.
Error Display
The following will be displayed if the ON time exceeds 1,500 s.
OVER US
The following will be displayed if the change in the light amount is low.
NON DETC
This may also be displayed when detecting a workpiece with a small change in light amount or a slow workpiece of 1,500 s or longer.
20
E3X-DA-S
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor.
WARNING
This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
The sensor is ready to detect within 200 ms after the power supply is turned ON. If the sensor and load are connected to separate power supplies, be sure to turn ON the sensor first. Time may be required for the incident level to stabilize after the power supply is turned ON.
CAUTION
Do not use the sensor with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the sensor with an AC power supply. Otherwise, explosion may result.
Operation at Power OFF
A pulse may be output when the power supply is turned OFF. Turn OFF the power supply to the load or the load line before turning OFF the power supply to the sensor.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation of the sensor. 1. Do not use the sensor in an environment where explosive or flammable gas is present. 2. Do not use the sensor in a location subject to splattering with water, streams, oils, or chemicals. 3. Do not attempt to disassemble, repair, or modify the sensor. 4. Do not apply voltages or currents that exceed the rated range to the sensor. 5. Do not use the sensor in an ambient atmosphere or environment that exceeds the ratings. 6. Wire the power supply correctly, including the polarity. 7. Connect the load correctly. 8. Do not short-circuit the load at both ends. 9. Do not use the sensor if the case is damaged. 10.Dispose of the sensor as industrial waste. 11.Do not use the sensor in locations subject to direct sunlight.
Mutual Interference Protection Function
Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-Sseries Units and E3C-LDA-series Units are used together.
Mounting
Connecting and Disconnecting Connectors
Mounting Connectors 1. Insert the Master or Slave connector into the Amplifier Unit until it clicks into place.
Insert
2. Attach the protective seals (provided as accessories) to the sides of master and slave connectors that are not connected.
Seal
Note: Attach the seals to the sides with grooves. Removing Connectors 1. Slide the slave Amplifier Unit away from the other unit. 2. After the Amplifier Unit has been separated, press down on the lever on the connector and remove it. (Do not attempt to remove a connector without first separating the Amplifier Unit from the other Units.)
Press down Lever
Remove
21
E3X-DA-S
Adding and Removing Amplifier Units
Adding Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track.
Fibers with E39-F9 Attachment
Fiber Unit
9 mm 13 mm
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place.
Click into place
9 mm 13 mm
Removing Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note: 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ambient temperature range on page 4. 2. Always turn OFF the power supply before joining or separating Amplifier Units.
2. Disconnecting Fibers Remove the protective cover and raise the lock lever to pull out the fibers.
Protective cover Locked Unlocked
Mounting the End Plate (PFP-M)
Use an End Plate if the Amplifier Unit might move due to vibration. Note: 1. To maintain the fiber properties, confirm that the lock is released before removing the fibers. 2. Be sure to lock or unlock the lock lever within an ambient temperature range between -10C and 40C.
Adjusting
Mutual Interference Protection Function
End Plate
Fiber Connection
The E3X Amplifier Unit has a lock lever for easy connection of the Fiber Unit. Connect or disconnect the fibers using the following procedures: 1. Connecting Fibers Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock lever.
The values that appear on the digital display may fluctuate somewhat due to light from other sensors. If this occurs, you can stabilize detection by setting a threshold that is close to half way between the incident levels with and without a sensing object.
Output Short-circuits
OVER/CUR will flash on the display if the output short-circuit protection function operates due to a load short-circuit in a control output. If this occurs, check the load connections.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power failure or static-electric noise, initialize the settings with the keys on the Amplifier Unit. ERR/EEP will flash on the display when a writing error has occurred.
Protective cover
Lock lever
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do not, however, slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation.
Locked
Unlocked Insertion position
Others
Fiber insertion mark Fiber
Protective Cover
Always keep the protective cover in place when using the Amplifier Unit.
9 mm
Mobile Console
The E3X-MC11-SV2 Mobile Console does not currently support the new Tough Mode and ON-delay + OFF-delay timer. You also cannot use the E3X-MC-S.
Note: Do not pull on the fiber, apply pressure on it, or otherwise subject it to excessive force when it is attached to the Amplifier Unit. (Use a force of 0.3 N*m max.)
Communications Unit
Use an E3X-DRT21-S Version 3 Communications Unit. This is not supported for the E3X-DA@R-S and E3X-DA@F-S (@: 21/51/7/9).
22
E3X-DA-S
Dimensions
Amplifier Units
Pre-wired Models E3X-DA21-S E3X-DA51-S E3X-DA21R-S E3X-DA51R-S E3X-DA21F-S E3X-DA51F-S
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Digital Display Area
Indicator 1 15.6 10 35.25
1. The indicators are as follows: E3X-DA21-S E3X-DA51-S
6.3
Operation indicator (2 ch) APC alarm output indicator Power tuning indicator
E3X-DA21R-S E3X-DA51R-S E3X-DA21F-S E3X-DA51F-S
Operation indicator (1ch)
Main display
Sub-display
DIN track mounting
4.3 141.1 180 101.45
Vinyl-insulated round cable Standard length: 2 m 2 32
4.5 5.65 3.4 Two, 2.4 dia.
(9)
12.5
Multiple connection diagram
L End Plate (sold separately) PFP-M
18.7
Hole for optical communications
(36.2)
70
(21.3)
Center of DIN track
DIN track (sold separately) PFP-@N
10 10
Fiber Attachment mounted (E39-F9) 10
With Mounting Bracket Attached
4.3 141.1 180 101.45
The number of expansion 1 2 3 4 5 6 7 8 9 10
L (mm) 10 20 30 40 50 60 70 80 90 100
Vinyl-insulated round cable Standard length: 2 m 2 32
4.5 5.65 3.4 Two, 2.4 dia. 10.3
(9)
12.5 Two, 3.2 dia. Holes 18.7
Hole for optical communications 4.3
(9.4)
16 70 Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately)
Mounting Holes
2-M3 3.4 4.4
16 28.1 16
Fiber Attachment mounted (E39-F9)
2. The cable specifications are as follows: E3X-DA21-S E3X-DA51-S E3X-DA21R-S E3X-DA51R-S E3X-DA21F-S E3X-DA51F-S 4 dia. cable / 5 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) 4 dia. cable / 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side.
23
E3X-DA-S
Wire-saving connector Models E3X-DA7-S E3X-DA9-S E3X-DA7R-S E3X-DA9R-S 10 E3X-DA7F-S E3X-DA9F-S
Digital Display Area
Indicator 1 15.6 35.25
1. The indicators are as follows: E3X-DA7-S E3X-DA9-S
6.3
Operation indicator (2 ch) APC alarm output indicator Power tuning indicator
E3X-DA7R-S E3X-DA9R-S E3X-DA7F-S E3X-DA9F-S
Operation indicator (1ch)
Main display
Sub-display
4.3
DIN track mounting
141.1 8.1 180
101.45
32
Dia. A 2 (9) 12.95
4.5 5.65 3.4 Two, 2.4 dia.
18.7 (36.2) 70
Hole for optical communications (21.3) Center of DIN track
Multiple connection diagram
L End Plate (sold separately) PFP-M
DIN track (sold separately) PFP-@N
10 Fiber Attachment mounted (E39-F9)
10
10
With Mounting Bracket Attached
4.3 141.1 8.1 180 101.45
The number of expansion 1 2 3 4 5 6 7 8 9 10
L (mm) 10 20 30 40 50 60 70 80 90 100
32
Dia. A 2 (9) 12.95
4.5 5.65 3.4 Two, 2.4 dia. 10.3
Two, 3.2 dia. Holes 18.7
Hole for optical communications (9.4) 16 70 4.3
Mounting Holes
3.4 2-M3 4.4
Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately)
2. The cable diameters are as follows:
16 28.1 16
E3X-CN21 (4 conductors) E3X-CN22 (2 conductors) 4.0 dia. E3X-CN11 (3 conductors) E3X-CN12 (1 conductor) 2.6 dia.
Fiber Attachment mounted (E39-F9)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side.
24
E3X-DA-S
Wire-saving connector
Master connector E3X-CN21
Edge of amplifier (7) 2,000+50 0
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector E3X-CN22
Edge of amplifier (7)
2,000+50 0
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Master connector E3X-CN11
Edge of amplifier (7)
2,000+50 0
Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector E3X-CN12
Edge of amplifier (7)
2,000+50 0
Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
25
E3X-DA-S
Accessories (sold separately)
Mounting Brackets E39-L143
(10.3) 5.3 7.3 26.8 Two, 3.2 dia. 3 16 3 Four, R1.7 3.4 1 3.4 1 7 160.1 2.5 34.8 22 16 3
Mounting Holes
2-M3
10.3 10 max. 7
Material: Stainless steel (SUS304)
End Plate PFP-M
10
11.5
50 M4x8 panhead screw
M4 spring washer 4.8 1 1.3 1.8 35.5 35.3 1.8
6.2
10
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
26
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
OMRON Corporation
Tokyo, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2010 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_1_1_0510 Cat. No. E396-E1-02 (0510)


▲Up To Search▲   

 
Price & Availability of E3X-DA51-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X